64 Incubator Analyzers
Ordering information
INCU-UNIPOWER Incubator Analyzer
Included accessories
3901000 Users Manual
97156 Soft-Sided Carrying Case
76060 Airflow Sensor
48583FG Universal AC Battery Charger
with Worldwide Mains Adapter Set
75101FG Serial Cable DB9F to DB9F
48582 Outside Temperature probe
holder
76058 Adapter for Radiant Infant
Warmer Assembly
48581 INCU PC Software (one CD)
Key features
Simultaneous measurement of
humidity, airflow, sound, and 4
independent temperatures
24-hour continuous testing
(battery); 35-hour continuous
testing (main power)
Battery operated
Adjustable measurement
intervals
Compatible with closed, forced-
convection incubators and open
infant warmers
Stand-alone measurement or
automated testing with PC
Windows
®
compatible INCU
software for easy data
collection, analysis, and
documentation
Numerical and full-color
graphical reports
Faulty incubator
controls lengthen
hospital stays, and
increase health-
care costs, making
thorough incubator
testing essential.
Designed around
AAMI and IEC stan-
dards that specify
incubator and radiant
warmer sound levels
and thermal char-
acteristics, the INCU
simultaneously mea-
sures airflow, relative humidity, sound, and four independent temperatures.
Adjustable measurement intervals allow technicians to configure the unit
to meet their facilities’ testing requirements. Technicians are free to do
other work while the device collects and records data.
INCU software lets technicians upload setup parameters and download
the test results to a PC file, or print the data in reports with full-color
charts and graphs.
Power supply
Input voltage range 100 V ac to 240 V ac
Input frequency range 47 Hz to 63 Hz
Battery Rechargeable sealed lead-acid type NP7-6 YUASA, 6 V, 7 Ah;
operates for 24 hours continuously; low-battery alert
Sound level
Measuring range 30 dbA to 80 dbA
Resolution 0.1 dbA
Accuracy +5 dbA @ 30 dbA to 80 dbA
Relative humidity (without condensation)
Measuring range 0 % to 100 % RH, non-condensing
Resolution 0.1 % RH
Accuracy ± 5 % RH for 0 % to 90 % RH at 77 °F to 104 °F (25 °C to 40
°C) or
± 5.3 % RH for 0 % to 100 % RH at 77 °F to 104 °F (25 °C to 40
°C)
Temperature measurement
Measuring range 5 °C to 70 °C (41 °F to 158 °F)
Resolution 0.1 °C (32 °F)
Accuracy +0.5 °C (+0.9 °F) +1 LSB of range from 25 °C to 40 °C (77 °F to
104 °F)
Airflow
Measurement range 0.1 m/s to 0.7 m/s
Resolution 0.01 m/s
Accuracy from 0.1 m/s to 0.5 m/s reading ± 0.1 m/s at temperature
25 °C to 40 °C (77 °F to 104 °F) and humidity 50 % RH ± 15 %
RH
General information
Measurement interval Via PC: Adjustable from 1 minute to 10 minutes
Storage temperature -20 °C to 50 °C (-4 °F to 122 °F)
Operating temperature 10 °C to 40 °C (50 °F to 104 °F)
Dimensions (LxWxH) 27 cm x 20 cm x 14 cm (10.6 in x 7.8 in x 5.5 in)
Weight 3 kg (6.6 lb)