Dynatech MP-7000 Spezifikationen Seite 62

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 68
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 61
62
Optional accessories
5000C-02 Performance Enhancement
Module 2: RS-232/printer
5000C-03 Performance Enhancement
Module 3: 100 records
5000C-04 Performance Enhancement
Module 4: Expanded memory
5000C-05 Performance Enhancement
Module 5: Waves/extended test
5000C-06 Performance Enhancement
Module 6: Data transfer
5000C-07 Performance Enhancement
Module 7: medCheck
5000C-08 Performance Enhancement
Module 8: Defibrillator
5000C-09 Performance Enhancement
Module 9: IV pump
5000C-10 Performance Enhancement
Module 10: CMMS interface
5000C-11 Performance Enhancement
Module 11: ESU
5000C-12 Performance Enhancement
Module 12: Sp0
2
5000C-13 Performance Enhancement
Module 13: Pacer
5000C-14 Performance Enhancement
Module 14: NIBP
5000C-WEDGE Wedge Adapter (eight
25 in serial ports, as well as AT
or PS/2 keyboard port)
9513-0212 Mini PC-style External
Keyboard (83 keys, AT or PS/2, wedge
adapter required
The medTester 5000C is an
automated system designed for
electrical safety testing and
performance verification. It is
compatible with most Fluke
Biomedical testing devices
and a majority of the popular
Computerized Maintenance
Management Systems (CMMS)
in the US. The medTester
5000C provides a completely
integrated solution for stan-
dardized and streamlined
testing and record keeping.
Modes of operation Fully equipped, with four operational modes: manual,
autosequence, medCheck, and remote control
Input power supply Line voltage/frequency input: 115 V ac ± 10 %/60 Hz
Test-receptacle type USA, 20 A
System/line voltage
Range (full scale) 200 V
Accuracy ± 5 % of range ± 1 LSD
Resolution 0.1 V
Equipment current
Range (full scale) 0 A to 20 A
Accuracy ± 5 % of range
Resolution 0.01 A
Ground resistance
Range (full scale)
0 Ω to 2 Ω
Accuracy ± 1 % of range
Resolution
0.001 Ω (1 mΩ)
Current source 100 mA dc
Measurement type True four-terminal technique
Test leads Kelvin (2) insulated clip
Leakage-current/voltage gradient
Ranges (full scale) 200 µA and 2000 µA or mV
Accuracy ± 1 % of reading DC + 3 LSD from 48 Hz to 1 kHz
± 2.5 % of reading + 3 LSD from 1 KHz to 100 KHz
± 5 % + 3 LSD from 100 KHz to 1Hz
Resolution 0.1 µA or 0.1 mV
Measurement type True-rms (autoranging) (ac + dc or dc only response)
Test-load selection ANSI/AAMI ES1 1993
Test-load impedence
1000 Ω ± 1 % at dc
Isolation test
Test selection (full scale) Patient leads to ground
Lead combinations All leads; or individual leads RL, RA, LA, LL, and V1/V6
(V1 through V6 tested as a single lead)
Available current
Limited by internal 120 kΩ resistor
Resolution 0.1 µA
Ranges (full scale) 200 µA and 2000 µA
medTester 5000C
Automated Biomedical Equipment Test System
Specications
Key features
• Easy verification of biomedical
equipment to manufacturer’s
specifications
• Ten preprogrammed and five
user-programmable electrical-
safety-testing sequences
• Convenient transfer of
equipment inventory and
testing procedures from CMMS
• Module options to automate
testing of most Fluke
Biomedical testing devices
• Automatic storage of detailed
test results for printing or
transfer to CMMS
• Compliant with ANSI/AAMI
(1993) and NFPA-99 (2005)
standards
• 20 A device testing with GFCI
protection
• Wedge hardware option for
extended serial port use,
optional PC-style keyboard and
barcode scan gun
Automation Solutions
riešenia na presné meranie
http://www.elso.sk
Seitenansicht 61
1 2 ... 57 58 59 60 61 62 63 64 65 66 67 68

Kommentare zu diesen Handbüchern

Keine Kommentare